A reckoning table
Solar share estimator
How much of a hybrid mini split's daily energy could your panels supply? Type in your own figures. The result is an estimate built only from the numbers you enter and the formula below.
Solar share estimator
The boxes hold example values (1000, 5, 0.8, 900, 8). Replace them with your own figures. Type numbers without thousands separators, such as 1000, not 1,000.
Estimate for one modeled day
These figures assume ideal timing: every solar kWh arrives while the unit can use it. Actual grid use and unused solar can be higher.
- Solar energy from the panels
- Energy the unit uses
- Solar share, upper bound
- Minimum grid or battery energy under ideal timing
- Minimum unused solar under ideal timing
solar, ideal timing grid or battery, at least
BTU per hour to watts
The box holds an example value, 12000. Replace it with your own figure, without a thousands separator.
This is the rate of heat the unit moves, not the electricity it uses. Use the unit's electrical input watts in the estimator above.
The formula
Solar energy = panel W × peak sun hours × derate ÷ 1000 (kWh a day)
Unit energy = electrical input W × run hours ÷ 1000 (kWh a day), taking the input as constant while the unit runs
Solar share = the smaller of 100 and solar energy ÷ unit energy × 100 (percent), an upper bound under ideal timing
Minimum grid or battery energy = the larger of 0 and (unit energy − solar energy), under ideal timing
Minimum unused solar = the larger of 0 and (solar energy − unit energy), under ideal timing
Convert watts = BTU/h × 0.29307107, with BTU/h read as BTU (International Table) per hour
Kilo means 1,000, so 1000 W for one hour is 1 kWh
What it assumes
- Panel watts are the nameplate ratings of all the panels feeding the unit, added together.
- Peak sun hours are the day's sunlight on the panels expressed as hours at 1,000 W per square metre, so one peak sun hour is 1 kWh per square metre. For your place, open the PVWatts Calculator, run your location, tilt and direction, and copy the monthly average daily Solar Radiation figure (kWh/m²/day) for the month you care about. That figure is an average, so treat the result as a representative day, not a forecast of any one day.
- Derate is the fraction of rated output left after losses such as heat, dust, wiring and the controller. It is a number between 0 and 1. If you have a total loss percentage, derate = 1 − loss ÷ 100.
- Electrical input watts are taken as constant for the whole run time you enter. A real unit's draw varies with load and conditions, and a spec-sheet rating is often above the running draw, so the unit energy here can be too high or too low.
- Timing is ignored. The share treats every solar kWh as if it arrived while the unit was running and could use it. Sunshine at noon cannot run the unit at night without a battery, and output above what the unit draws at that moment goes unused. Read the share as an upper bound, and read the grid or battery and unused-solar rows as minimums. Actual grid use and unused solar can be higher.
- BTU/h is capacity, not consumption. The converter turns the heat a unit moves into watts. It does not tell you the electricity the unit uses.
- Input limits are the calculator's own. Panel rating up to 100,000 W, peak sun hours and run hours up to 24, electrical input up to 20,000 W and capacity up to 1,000,000 BTU/h keep the arithmetic sensible. They are not claims about real systems.
Where the numbers come from
- Peak sun hours for your location: PVWatts Calculator, National Laboratory of the Rockies (NLR).
- Where the monthly Solar Radiation output in kWh/m²/day is defined: PVWatts API V8 documentation, National Laboratory of the Rockies (NLR).
- One sun hour as 1 kWh per square metre: Ute Mountain Tribe 1994 Project, Office of Indian Energy, U.S. Department of Energy.
- Kilo as 1,000: Metric (SI) Prefixes, National Institute of Standards and Technology (NIST).
- The conversion factor 1 BTUIT/h = 0.29307107 W: NIST Guide to the SI, Appendix B.8: Conversion factors, National Institute of Standards and Technology (NIST).
- Panel and unit ratings: the manufacturer's own specification sheets. The guides list where each figure was published.